• Ultra-low temperature air source heat pump unit 5P/6P/8P/10P/13P
Ultra-low temperature air source heat pump unit 5P/6P/8P/10P/13P
+

Ultra-low temperature air source heat pump unit 5P/6P/8P/10P/13P

R410A green environmental protection refrigerant is adopted
  • Commodity name: Ultra-low temperature air source heat pump unit 5P/6P/8P/10P/13P

Product Description

Product Features

1. Copeland ZW series high-efficiency air supplement and enthalpy increase compressor (high-efficiency compressor designed for heat pump working conditions), realizing "quasi-two-stage compression" of air conditioning system, and one compressor realizing 2
stage compression
2. R410A green environmental protection refrigerant is adopted, which does not contain chlorine element that destroys the ozone layer. The refrigerant is stable in nature, non-toxic and has zero damage to the ozone layer (0DP is 0), and there is no prohibition period.
3. "TTSP" independent intelligent defrosting technology, the unit automatically determines the defrosting conditions, and truly realizes "more frost, more frost, less frost, less frost", defrosting is more accurate, water temperature fluctuations caused by defrosting are reduced, and the best energy-saving scheme is realized.
4. The fin non-uniform flow path design should deal with the uneven wind field (small air volume at the bottom, poor heat exchange, and non-uniform distribution to make full use of the heat exchange area), so that the wind side heat exchanger can play the best heat exchange capacity in actual application.
5, "supercooling ice suppression" design, the bottom of the fin heat exchanger has been flowing high temperature medium, can effectively prevent the winter defrosting water in the bottom of the fin freezing accumulation problem, to avoid its damage to the water collection tray and heat exchanger copper tube.
6. Imported high-performance electronic expansion valve, PID control automatic adaptation, air supplement control technology, exhaust temperature control technology, high stability, good adjustment, high accuracy, and full improvement system
The best performance of each 1 component within the system.
7. Efficient and stable heating at -35 ℃ low temperature environment. At the same time, multi-working conditions and multi-defrosting cycle reliability experiments, transportation experiments, water spraying experiments, noise experiments, etc. are carried out to ensure stable and reliable operation of the equipment.
8. Modular design, compact structure, small footprint, easy installation, and free combination according to needs.

Parameter

Unit Model LFRM 5DK 6DK 8DK 10DK 13DK
Heating capacity (7 ℃) Kw 15.2 18.5 24.1 30.4 40.1
Heating capacity (-12 ℃) Kw 10.6 12.5 15.9 20.8 26.2
Refrigerating capacity (35 ℃) Kw 11.5 13.6 16.8 21.9 27.8
Rated water flow Kw 2.0 2.3 3.1 3.8 4.8
Rated lift m³/h 18 18 18 18 25
Heating reference area m 100-120 120-140 160-180 200-240 240-260
Nozzle specification (galvanized pipe) m2 DN32 DN32 DN40 DN40 DN40
Nozzle specification (hot melt pipe)   DN40 DN40 DN50 DN50 DN50
7 ℃ heating input power Kw 4.93 5.9 6.9 9.9 12.8
Rate -12 ℃ Heating Input Power Kw 4.13 5.0 5.9 8.9 10.8
35 ℃ Refrigeration Input Power Kw 4.02 5.1 6.1 8.6 10.8
Power   1ph-220V-50Hz/3ph-380V-50Hz 3ph-380V-50Hz
Refrigerant   R410A/R22
Compressor   jet enthalpy compressor
Fan   6 extremely low noise axial flow fan
Heat Exchanger   Efficient tank heat exchanger
Flow control mode   Electronic expansion valve
Scope of Work   43℃--35℃
Noise dB(A)   55 56 58 60 60
Overall dimension Length x width x height mm 1050x470x1320 1050x500x1320 1240x560x1400 1320x660x1400 1320x660x1400
Weight Kg 125 130 160 190 235
Wiring Copper Wire (quar.) 6/2.5 6/2.5 4 6 6

Rated refrigeration condition:
The inlet temperature of cold water is 12 ℃, the outlet temperature is 7 ℃, the dry bulb temperature of outdoor environment is 35 ℃, and the wet bulb temperature is 24 ℃;
Rated heating condition:
The inlet temperature of hot water is 36 ℃, the outlet temperature is 41 ℃, the dry bulb temperature of outdoor environment is -12 ℃, and the wet bulb temperature is -14 ℃. If there are slight differences with the actual parameters due to technical improvement, please refer to the relevant instructions of the actual product.

Get A Quote

Note: Please leave your contact information, our professionals will contact you as soon as possible!

Submit Now

What Else Might You Learn?

Introduction to Double Stage Coupled Heat PumpHeating System

Two-stage compression resistance to severe cold -36 ℃ stable heating

Special hydraulic integrated module for heat pump

Its main purpose is to simplify the installation process of water

Special hydraulic integrated module for heat pump

Its main purpose is to simplify the installation process

Special hydraulic integrated module for heat pump

Its main purpose is to simplify the installation process

Customized services

*Note: Please be sure to fill in the information accurately, and keep the communication unblocked, we will get in touch with you as soon as possible


To: Renqiu Aorun Heating Equipment Co., Ltd.


I Want More Details. Product Requirement: Custom Made: Delivery Time: Payment: Shipping: Usage:
((Maximum 5 files. Supports jpg, jpeg, png, gif, txt, doc, pdf, xls, docx, xlsx, less than 5MB))
Send Now